 ACB

L Type ACB Unelec (GE)

L Type ACB (Spectronic Series)

A powerful ACB’s was design and manufacture by Unelec company St Quentin France.

Rated Current in 40⁰C From 640A To 2000A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 130 kA

Fixed & with drawable (Rotary handle)

Protection unit can be installed : DN Type , RMS Type & RV type

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

**************************************************************************************************

S Type ACB (Spectronic Series)

A Full Range ACB’s was design and manufacture by Unelec (GE) company.

Rated Current in 40⁰C From 800A To 6400A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 55 To 120 kA

Fixed & with drawable (Spring charge)

Protection unit can be installed : RMS Type & RV type.

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

S type ACB's Unelec (GE)

**************************************************************************************************

CNP Type ACB'S Unelec (GE)

CNP Type ACB

A Standard ACB’s was design and manufacture by Unelec (GE) company St Quentin France.

Rated Current in 40⁰C From 800A To 2500A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 55 To 60 kA

Fixed & with drawable (Rotary handle)

Protection unit can be installed : DN Type & RW Type.

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

**************************************************************************************************

SP (SPE) Type ACB (Spectronic Series)

A Standard ACB’s was design and manufacture by Unelec (GE) company St Quentin France.

Rated Current in 40⁰C From 400A To 2500A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 55 To 60 kA

Fixed & with drawable (Rotary handle)

Protection unit can be installed : RV type & RMS Type.

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

**************************************************************************************************

M-Pact ACB's GE

M-Pact or M-pact Plus Types ACB

A modern ACB’s was design and manufacture by GE company UK.

Rated Current in 40⁰C From 800A To 4000A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 50 To 80 kA

Fixed & with drawable (Rotary handle)

Protection unit can be installed : M-Pro Type.

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

**************************************************************************************************

EntelliGuard G Types ACB

A high technology ACB’s was design and manufacture by GE company UK.

Rated Current in 40⁰C From 400A To 6400A

Rated ultimate short circuit breaking capacity (kA) (Icu) : 50 To 150 kA

Fixed & with drawable (Rotary handle)

Protection unit can be installed : GT Type.

All the accessory are able for inquiry and replacement. (EA , MV, MVR, AUX , Fault & Motor unit in all ranges)

All Part are available for replacement or repair also complete breaker is available. (contact us)

ENTLIGURD Type ACB's GE